West Mountain Radio Battery Box Technical Information Seite 69

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 80
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 68
69
West Mountain Radio Operating Manual
Hands Free Testing
An external software program, or script, can initiate a hands-free
test by executing the software with the /test command-line options.
For example:
"C:\Program Files\CBA III\WMRCBA2.exe" /test
discharge 2 /cutoff 10.5 /open result.bt2
The software will remain open and run the test until the test has
completed. For most tests, it is completed when battery voltage
has dropped below cutoff voltage. For multiple-discharge test, test
will complete after the specied duration has expired -or- the cutoff
voltage is reached, which ever happens rst.
When the test is complete, the software will close and return an
error code to the external software program or script.
A batch le is present in the executable directory that shows a
working of example of calling the .EXE and handling the returning
error level.
Seitenansicht 68
1 2 ... 64 65 66 67 68 69 70 71 72 73 74 ... 79 80

Kommentare zu diesen Handbüchern

Keine Kommentare